As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FUME EVENT ON FINAL AT 3000FT IN AFT CABIN. X-BLEED WAS SHUT + PACK 2 TURNED OFF REMOVED SMELL-PERFOMED TSM 05-50-00-810-831 FUME EVENT RAN PACK # 2 AND PERFORMED INSPECTION APU + ENG DUCTS NO FAULTS FOUND NO SMELL DUPLICATE SYSTEM IS GOOD FOR SERVICE.