What was found
SMELL OF ELECTRICAL PLASTIC TYPE SMELL THROUGH DESCEND AND ARRIVAL INTO CLT. DESCRIPTION OF ODOR/FUMES: PERSISTENT, SMOKE/BURNING/ELECTICAL SMELL. APPARENT CABIN SOURCE: UNKNOWN. FLIGHT DECK, FWD CABIN, MID CABIN, AND AFT CABIN. NO VISIBLE SMOKE/HAZE. MEDICAL ATTENTION REQUIRED, EMS.-PERFORMED T/S OF ODOR SOURCE IAW TSM 05-50-00-810-831-A NO DEFECTS FOUND AT THIS TIME. PERFORMED LEVEL A DECONTAMINATION OF THE ECS SYSTEM IAW AMM 21-00-00-615-802-A. A/C OK FOR SERVICE MOC 119918