Service difficulty report · Relay · Doug DC931

Difficulty date
July 7, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N934ML
Make and model
Doug DC931
Aircraft serial
47526
Part
Relay
Part number
914F5674
Condition
Failed
Location
Right
Stage of operation
IN
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PIT - FLT 202 - APPARENTLY THE RIGHT A/C BUS HAS AN APU RELAY STICKING WHICH WILL NOT ALLOW ANY OTHER POWER SOURCE TO POWER THE RIGHT A/C BUS. THIS OCCURS EVEN WITH THE APU SHUT DOWN. RESET CROSS-TIE RELAY. APU GEN SYSTEM INOP. TRANSFERRED DMI LOG NR 00712 IAW MEL 24-1-2 CAT C. REMOVED AND REPLACED RIGHT AUX RELAY IAW DC-9 MM J24-20-6. PERFORMED A/C CROSS-TIE CHECK WITH ENGINES NR 1 AND NR 2 RUNNING. A/C CROSS-TIE CHECK WITH ENGINES NR 1 AND NR 2 RUNNING. A/C CROSS-TIE CHECKS GOOD. OPS CHECK NORMAL IAW FCOM. CLEARED DMI NR 00712. PLACARD REMOVED AND DISPATCH NOTIFIED THROUGH MX CONTROL. (M)