Service difficulty report · Housing · Doug DC1010

Difficulty date
September 17, 2000
Submitted
November 15, 2000
Operation
Air carrier
Aircraft
N135AA
Make and model
Doug DC1010
Aircraft serial
47830
Part
Housing
Condition
Cracked
Location
Interlock Fuse
Stage of operation
LD
How discovered
O
Nature of condition
K, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HNL - FLT 25 - ON TOUCHDOWN, FLAIR CAUTION LIGHT APPEARED AND LOSS OF HYD FLUID BECAME EVIDENT. BOTH PUMP PRESS LOW LIGHTS ILLUMINATED. NR 3 HYD PRESS OBSERVED AT ZERO, AND NR 3 HYD QTY OBSERVED AT ZERO. NR 2 BRAKE SYSTEM AT 3000 PSI. SYSTEM 3 HYD PUMPS TURNED OF. AIRCRAFT LANDED WITH NORMAL FLIGHT CONTROL OPERATIONS. FOUND BOGIE TRIM CONTROL INTERLOCK FUSE HOUSING CRACKED. REMOVED AND REPLACED VALVE PER MM 32-31-06. FILTERS CHECKED, SYSTEM FILLED, GROUND RUN AND OPS CHECK NR 3 HYD SYSTEM GOOD. (M)