What was found
ETOPS SIGNIFICANT SYSTEM, NR 1 ENG IDG DPI POPPED, FOUND ON OVERNIGHT. ACCOMPLISHED AMM 24-11-01, 8-1-07, 6091 LEAK CK OF FILTER AND MAG DRAIN PLUG AND RESERVICE AFTER ENG RUN PENDING. OPS CK LK CK OF FILTER MAG DRAIN PLUG OIL QUANTITY CK OK FOR SVC. NO FAULTS NOTED ON EICAS.