What was found
ENG L SYS FAIL DISPLAYED. FOUND 10P BOX FAULT ON EEC FAULT REVIEW AND CURRENT FAULT REMOVED AND REPLACED 10P PER MM 73-21-11, COND SAME. REMOVED AND REPLACED NR 1 EEC ASSY PER AMM 73-21-01. NO FAIL NOTED ON ENG RUN.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ENG L SYS FAIL DISPLAYED. FOUND 10P BOX FAULT ON EEC FAULT REVIEW AND CURRENT FAULT REMOVED AND REPLACED 10P PER MM 73-21-11, COND SAME. REMOVED AND REPLACED NR 1 EEC ASSY PER AMM 73-21-01. NO FAIL NOTED ON ENG RUN.