ETOPS SIGNIFICANT SYSTEM - R ENG FIRE LP 2 EICAS MSG. CLEANED CONNECTIONS ON LOWER RT ENGINE FIRE LOOP 2. CLEARED EICAS MSG. PERFORMED ENGINE FIRE TEST. ALL TESTS NORMAL. OK FOR SERVICE AMM 26-10-00.