What was found
ETOPS SIGNIFICANT SYSTEM - AILERON LOCKOUT AT 310KTS LASTED FOR 2 MIN(CLIMB OUT). T/S PER FIM 27-11-00 FIG. 104.LEFT LOCKOUT ACTUATOR FAILED TWICE DURING CHECK. REMOVED AND REPLACED SAME PER AMM 27-11-44, SYS CHECKED OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYSTEM - AILERON LOCKOUT AT 310KTS LASTED FOR 2 MIN(CLIMB OUT). T/S PER FIM 27-11-00 FIG. 104.LEFT LOCKOUT ACTUATOR FAILED TWICE DURING CHECK. REMOVED AND REPLACED SAME PER AMM 27-11-44, SYS CHECKED OK.