What was found
AFTER V1 FIRE WARNING HORN SOUNDS CONTINUOSLY WITH NO OTHER INDICATIONS. R & R BELL CHIME AURAL WARNING CARD IAW MM31-51-04. OPS CHECKED NORMAL, OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER V1 FIRE WARNING HORN SOUNDS CONTINUOSLY WITH NO OTHER INDICATIONS. R & R BELL CHIME AURAL WARNING CARD IAW MM31-51-04. OPS CHECKED NORMAL, OK FOR SERVICE.