What was found
ETOPS SIGNIFICANT SYS - "STBY INVERTER" MESSAGE DISPLAYED ON EICAS. REPLACED THE STATIC INVERTER IAW AMM 24-33-03. OPS CHECK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYS - "STBY INVERTER" MESSAGE DISPLAYED ON EICAS. REPLACED THE STATIC INVERTER IAW AMM 24-33-03. OPS CHECK OK.