What was found
LONGITUDINAL FLOOR SUPPORT STRUCTURE BETWEEN BS 160-200 AND RBL 6-9 HAS CORROSION AND DETERIORATED COATING. R & R NEW FLOOR SUPPORT IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LONGITUDINAL FLOOR SUPPORT STRUCTURE BETWEEN BS 160-200 AND RBL 6-9 HAS CORROSION AND DETERIORATED COATING. R & R NEW FLOOR SUPPORT IAW SRM 51-40-02.