What was found
DURING DECENT INTERMITTENT ECAMS NR 2 ENGINE FIRE LOOP A FAULT. ACCOMPLISHED TSM 26-12-00 FOUND LOOP A INSULATOR MISALIGNED, REPOSITIONED INSULATOR NR 2 ENGINE FDU, GROUND OPS CHECKED OK, IAW AMM 26-12-00-740-804 A
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING DECENT INTERMITTENT ECAMS NR 2 ENGINE FIRE LOOP A FAULT. ACCOMPLISHED TSM 26-12-00 FOUND LOOP A INSULATOR MISALIGNED, REPOSITIONED INSULATOR NR 2 ENGINE FDU, GROUND OPS CHECKED OK, IAW AMM 26-12-00-740-804 A