What was found
AILERON LOCKOUT ADVISORY EICAS MESSAGE DISPLAYED & LOCK AMBER OVERHEAD LIGHT ILLUMINATED WHILE CLIMBING THRU FL 220 & REMAINED ON FOR DURATION OF THE FLT. TROUBLESHOT IAW FIM 27-11, FAULT TREE 804, R SAM BOX HAD FAULT RT AILERON LOCK OUT. RESET IAW FIM. NO FAULTS NOTED, OK FOR SERVICE. PERFORMED TEST 65. "PASSED" REMAINS CAT 3.