What was found
ETOPS SIGNIFICANT SYSTEM - INFO TO MAINTENANCE, UPON STARTING ENG NR 2 GOT ECAM ENG 2 START FAULT AND ENG 2 IGN A FAULT, PER MAINT. REQUEST WE RESET A3 AND Q40 CIRCUIT BREAKERS. AFTER CIRCUIT BREAKERS RESET AND RESTART ENG NR 2 FAULT CLEARED. PERFORMED OPERATIONAL TEST OF ENG NR 2 IGNITION SYSTEM PER AMM 74-00-00-710-802-A. IGN A AND B SYSTEM TESTED OK. NO FAULTS NOTED. OK FOR SVC.