What was found
ETOPS SIGNIFICANT SYSTEM - ECAM APU FAULT. // T/S PER A330 TSM 49-62-00-810-916 4 D NO DEBRIS ON ELECTRICAL CHIP DETECTOR OR IN OIL FILTER ELEMENTS PER STEP 4.D SUSPECT GEN SCAVENGE 591CT32 AND LUBRICATION 59KT37 DELTA P SWITCHES AT FAULT. R/R GEN SCAV DELTA P 59K732 PER A330 AMM 49-41 LUBRICATION 59KT36 DELTA P SWITCH STILL REQUIRES TO BE REMOVED AND REPLACED. REMOVED AND REPLACED LUBE DELTA P SWITCH PER AMM 49-41, OK FOR SERVICE, OPS AND LEAK CHECK GOOD NO MSG OK FOR SERVICE.