What was found
ETOPS - DUE TO REPEAT ECAM WARNING ENG 2 MINOR FAULT. NEED TO REPLACE PCU // REMOVED & REPLACED ENG #2 PCU PER AMM 73-21-35. OPS CHECK GOOD. OK FOR SVC. CONTROL, UNIT PN OFF 43-7321-9-0003 SN 80771 ON 43-7321-9-0003 SN 81750
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - DUE TO REPEAT ECAM WARNING ENG 2 MINOR FAULT. NEED TO REPLACE PCU // REMOVED & REPLACED ENG #2 PCU PER AMM 73-21-35. OPS CHECK GOOD. OK FOR SVC. CONTROL, UNIT PN OFF 43-7321-9-0003 SN 80771 ON 43-7321-9-0003 SN 81750