What was found
ETOPS - INFO TO MX: ENG1 FIRELOOP A FAULT DURING CLB. ECAM CLEARED. BITE FDU1 NO FAULTS. CHECK FDU1 J-K 1.493 OHMS, J TO GND OPEN, K TO GND OPEN PER ASM 26-12-01. REPLACED FDU1 PER AMM 26-12-34 OPS CHECK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - INFO TO MX: ENG1 FIRELOOP A FAULT DURING CLB. ECAM CLEARED. BITE FDU1 NO FAULTS. CHECK FDU1 J-K 1.493 OHMS, J TO GND OPEN, K TO GND OPEN PER ASM 26-12-01. REPLACED FDU1 PER AMM 26-12-34 OPS CHECK OK.