As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS - INFO TO MAINT: DURING CLIMB, WE GOT ECAM ENG 2 FIRE LOOP A FAULT TWICE. BOTH TIMES LASTED UNDER A MINUTE AND CLEARED ON ITS OWN. PERFORMED RESISTANCE TEST PER AMM 26-12-00-810-805-A. FOUND PINS J&K 1.490O, INSULATION RES. PIN J-GRD-0.00MO PINS K TO GRD - 0.00MO. REMOVED & REPLACED ENG 2 LOOP A FWD FIRE DETECTOR 4002WD1 PER AMM 26-12-17. OPS CHECK OK FOR SERVICE.