What was found
ETOPS - COCKPIT TEMPERATURE FLUCTUATIONS IN FLIGHT ONLYM TEMPERATURE MODULATES BETWEEN 70 DEGREES F- 82 DEGREESF. REMOVED AND REPLACED CKPT UPSTREAM DUCT TEMP SENSOR. (648HK) IAW A330 AMM 21-63-15. SYSTEM TEST GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - COCKPIT TEMPERATURE FLUCTUATIONS IN FLIGHT ONLYM TEMPERATURE MODULATES BETWEEN 70 DEGREES F- 82 DEGREESF. REMOVED AND REPLACED CKPT UPSTREAM DUCT TEMP SENSOR. (648HK) IAW A330 AMM 21-63-15. SYSTEM TEST GOOD.