What was found
HNL - OVERNIGHT CHECK, FOUND NR 1 RIGHT SLAT NOT FULLY EXTENDED, FOUND DEFECTIVE CABLE, NR 2 RIGHT SLAT DAMAGED INBOARD END AND RIGHT WING L/E CAP DAMAGED OUTBOARD OF NR 3 SLAT TRACK. REPAIRED WING L/E CAP AND NR 2 SLAT, REPLACED SLAT CARRIAGE ASSY AND NR 1 SLAT CABLES PER MM 27-80-02. OPERATIONAL CHECK OK. (M)