What was found
DELAYED LIGHT OFF. NOZZLE FLOW RATE TESTED AT THE MINIMUM FLOW RATE AT 125 PSIG. INSPECTED NOZZLE UNDER MAGNIFICATION, CHECK OK. RE-SHIMMED TO ADJUST FUEL RATE TO A HIGHER SETTING. UNIT TESTED SATISFACTORY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DELAYED LIGHT OFF. NOZZLE FLOW RATE TESTED AT THE MINIMUM FLOW RATE AT 125 PSIG. INSPECTED NOZZLE UNDER MAGNIFICATION, CHECK OK. RE-SHIMMED TO ADJUST FUEL RATE TO A HIGHER SETTING. UNIT TESTED SATISFACTORY.