What was found
DURING SINGLE ENGINE TAXI, NR 2 AC GENERATOR ON LINE, NR 1 STANDBY HYDRAULIC PUMP FAILED CAUSING LOSS OF NR 1 HYDRAULIC PRESSURE. RECYCLED NR 2 AC GENERATOR, NR 1 STANDBY HYDRAULIC PUMP RETURNED TO NORMAL. INSPECTED BRAKES AND HYDRAULIC SYSTEM, NO LEAKS NOTED. STARTED AND TAXIED AIRCRAFT AROUND AIRPORT, COULD NOT DUPLICATE.