What was found
ON CLIMB-OUT, BOTH STALL WARNING STICK SHAKERS ACTIVATED AND FIRST OFFICER'S FAST SLOW INDICATOR SHOW 10 TO 20 KNOTS SLOW. PULLED AND COLLARED CIRCUIT BREAKERS STALL WARNING AND HEATER NR 2, STALL FAIL MON 2, STALL TRANSPONDER AND HEATER 2. REMOVED AND REPLACED STALL WARNING TEST SWITCH INSTALLATION CHECKED GOO IAW WORKCARD 27-33-00. CHECKED CALIBRATION OF NR 2 STALL WARNING LIFT TRANSDUCER IAW WORKCARD 27-30-05F. OPS CHECKED GOOD AT THIS TIME.