What was found
LANDING GEAR DOOR AMBER LIGHT REMAINED ILLUMINATED AFTER GEAR OPEN. VISUAL INSP CONFIRMED FWD DOOR OPEN. CREW PERFORMED CHECKLIST CYCLED GEAR, LANDED WITHOUT FURTHER INCIDENT. INSPECTED NR 1 MAIN GEAR DOOR ACTUATOR AND PROX SENSOR. NO DEFECTS NOTED, CHECKED SENSOR GAP. GAP CHECKED GOOD. JACKED ACFT, CYCLED GEAR SEVERAL TIMES, NO DEFECTS NOTED. OK FOR SERVICE, IAW MM 32-10-21 AND 32-10-36.