What was found
AFTER TAKEOFF, RETRACTED GEAR, AFTER 2 MINUTES, GOT THE NOSE GEAR RED UNSAFE LIGHT WITH ASSOCIATED IN TRANSIT LIGHT ON SELECTOR HANDLE FOR APPROX 30-40 SECONDS. NOTED ASSOCIATED THUMP AND ALL CLEARED.COMPLIED WITH ALTERNATE GEAR EXTENSION. JACKED AND SWUNG GEAR SEVERAL TIMES, NO DEFECTS NOTED. R & R PSEU FOR TROUBLESHOOTING. REF MM 32-61-50. SWUNG GEAR SEVERAL MORE TIMES. OPS CHECKED GOOD AT THIS TIME.