What was found
AFTER GEAR RETRACTION, NOSE GEAR DOORS OPENED AND NOSE GEAR PARTICAIALLY EXTENDED AND RETRACTED TWICE WITH ALL ASSOCIATED LIGHTS. JACKED ACFT AND PERFORMED LANDING GEAR, OPS CHECK 3 TIMES. CLEARED PSEU MEMORY. PERFORMED OPS CHECK 3 TIMES. PSEU CODED 55 AND 53 OBSERVED. R & R GEAR SELECTOR HANDLE. R & R PSEU. PERFORMED OPS CHECK 15 TIMES. MEASURED INDUCTANCE AND SERIES RESISTANCE USING BOB OF ALL PROX SENSORS ASSOCIATED WITH DISCREPANCY.