What was found
ABORTED TAKEOFF DUE TO AUTO FEATHER DID NOT ARM. AFTER ABORT, CREW TESTED A/F. TESTED NORMALLY. PUSHED POWER LEVERS UP, ARM LIGHT ILLUMINATED AT 76 PERCENT. INSPECTED POWER LEVER MICROSWITCHES 6121-S6, 7, 8 AND 9. NO DEFECTS NOTED. INSPECTED NR 1 AND NR 2 TSCU CONNECTOR PLUGS. NO DEFECTS NOTED. FOUND SMALL AMOUNT OF FLUID AND CLEANED CONNECTOR PLUGS. REINSTALLED NR 1 AND NR 2 CONNECTOR PLUGS. REMOVED AND REPLACED BOTH TSCU. OPS CHECKED GOOD. RUN UP MANUAL.