What was found
NR 2 ITT WENT TO ZERO IN FLIGHT. R & R T6 WIRING HARNESS FROM K FLANGE TO CONNECTOR AT FIREWALL IAW -8 POWER PLANT BUILD UP 71-00-02. OPS CHECKED GOOD IAW RUN UP MANUAL. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.