What was found
NOSE GEAR RED UNSAFE LIGHT ILLUMINATED FOR APPROXIMATELY 10 SECONDS WITH ASSOCIATED CLUNK. THE RED NLG LIGHT EXTINGUISHED FOR APPROXIMATELY 10 SECONDS, THEN EXTINGUISHED ON LANDING GEAR RETRACTION. NLG EXTENDED FINE. NO NOISE ON EXTENSION. INSPECTED NLG AND PROXIMITY SENSORS. NO DEFECTS NOTED. SWUNG GEAR 20 TIMES, NO DEFECTS. R & R PSEU DUE TO INTERMITTENT CARD FAULT. COMPLIED WITH FURTHER GEAR SWINGS. NO DEFECTS NOTED IAW MM 32-61-50. OK FOR SERVICE.