What was found
EICAS SPOILER FAILED MESSAGE WITH SPOILER DEPLOYMENT, DURING CLIMB OUT. HAPPENED AROUND 3000 FEET, SPOILERS FELT DEPLOYED, CIRCUIT BREAKERS WERE PULLED IAW QRH. TROUBLESHOT IAW FIM 27-63-00-810-802-A AND DETERMINED TO BE TRANSITORY CONDITION. PERFORMED INSPECTION OF ALL SPOILER PROXIMITY SENSORS AND FOUND GLYCOL INSIDE FOUR CONNECTOR PLUGS FOR THE PROXIMITY SENSORS. CLEANED THE CONTAMINATION AND PERFORMED A SPOILER SYSTEM OPERATIONAL CHECK IAW AMM 27-63-01. OPS CHECKED GOOD.