What was found
EICAS CT MESS, RUDDER SYS 2 INOP, IN FLT (TAKE-OFF). R+R RUDDER #2 PRESSURE SWITCH IAW AMM 27-23-04. OPS CHECK GOOD OK FOR SERVICE. EICAS MESS, RUDDER SYS 2 INOP, IN FLT. T/S IAW FIM TASK 27-23-00-810-802-A. FOUND RUDDER PRIORITY RELAY K0384 TO AT FAULT. R/R'D RELAY IAW MM 20-13-02/400, OPS CK GOOD TO 160 KTS.