What was found
PDIS 650, 31-41, 13APR21 PHL CLOSE, 300 FEET AFTER ROTATION, EICAS DISPLAY FLASHED BRIGHTLY AND WENT BLANK MOMENTARILY FOLLOWED BY AN ELECTRICAL ODOR. R&R'D EICAS DISPLAY UNIT AS REQUIRED PER AMM 34-22-01-400-801-A, OPS CHECK IAW 34-22-00-700-801A GOOD ON GROUND AT THIS TIME, OK FOR SERVICE.