What was found
DURING TAKE OFF E2 LOW FUEL PRESS DISPLAYED ON EICAS WHEN OPERATING ON PUMP 2B. VERIFIED 2A AND 2C OPERATING NORMALLY... P/C C/B A4 ON LH DC DIST. BOX. T/S IAW FIM 28-45-00-810-802-A. R & R ELECTRIC FUEL PUMP 2B IAW AMM 28-21-01. UPON REMOVAL FOUND DEBRIS ON PUMP INTAKE SCREEN, PROBABLE CAUSE OF ISSUE. OPS CHECK IAW AMM 28-45-00 GOOD.