As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CLIMB TO 10,000 FEET LOUD WHINING NOISE FROM INSTRUMENT PANEL. P/C C/B F-5 . C/W MNT PROCEDURE. FWD ELEC COMP BAY RECIRC FAN. R&R RECIRC FAN #2 INVERTER IAW AMM 21-26-03. OPS CHECK GOOD IAW AMM 21-26-00. A/C OK FOR SERVICE AT THIS TIME. CLEAR MEL 21-11-3