What was found
INSPECTION TYPE:C2 REPAIR NR 5 SLAT DENTS (2 EACH ) LOCATED ON THE T/E WEDGE FWD SURFACE 66.5 INCHES AND 70 INCHES FROM I/B END OUT OF LIMITS DUE TO THE PROXIMITY TO EACH OTHER. FABRICATED REPAIR DOUBLERS, FILLED DENTS & INSTALLED DOUBLERS SEALED & REFINISHED IAW 51-70-10-02R NDT PT 1 51-01-01 + PT 6 51-00-19.