What was found
INSPECTION TYPE:C ("04 ITEM") FWD CARGO DOOR JAM AT STA 620 HAS 2EA MISDRILLED HOLES HOLES IN WEB & CHORD. REMOVED DAMAGED BRACKET PER SRM 51-40-02. DIM OF DAMAGE HOLES: A UPPER HOL .330" ORIG HOLE .250 B LWR HOLE .315 IRUG GIKE .250 PER DRW NT143N8522. REMOVED RT SIDEWALL PNLS FROM STA 620 TO 740 TO FOM IAW AMM25-50-02. REMOVED STOP TIE DOWN FITTING AT STA 600 TO FOM IAW SRM 51-40-01. REMOVED CNTR & AFT SCUFF PLATES IAW SRM 51-40-02.