What was found
INSPECTION TYPE:C DENT IN AFT CARGO COMPARTMENT FUSELAGE FRAME AT STA 1500, S-26L. REMOVED TRANSITION PANEL IAW SRM 51-40-02 2. DENT FOUND TO BE OUT OF LIMIT IAW SRM53-00-01A FIG 101. HFEC AT CUT OUT HOLES IAW NTM 51-00-01PT6/16PT6, NO CRACKS FOUND. FABRICATED REPAIR PARTS PER MAE TR NR T9/791324 7075 -O HT T6 0.071 INCH. ACC REPAIR PER SRM 53-00-07-2R5 FIG 201 DETAIL I. INSPECT THRESHOLD AT 48883 FC, REPEAT EVERY EACH 12000 FC INTERVALS.