What was found
INSPECTION TYPE:C2 MAIN CARGO DOOR BS 570 STUB FRAME HAS TOOLING DAMAGE 2.6 - 8.3 INCHES BELOW STR 15L I/B FLANGE AND FWD RADIUS. REMOVED DAMAGE, FABRICATED REPAIR ANGLE, STRUCTURAL FILLER, INSTALLED REPAIR ANGLE REPAIR STRUCTURAL FILLER AND REPAIR CLIP IAW ATS ER NO 09-3154 DATED 26JUNE09.