What was found
INSPECTION TYPE:C2 FWD CARGO BAY DOOR CUTOUT LOWER THRESHOLD ATTACH FITTING STATION 607 LOWER AFT FASTENER MOUNT HOLE IS CORRODED. REMOVED AND REPLACED PER SRM 51-40-02-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 FWD CARGO BAY DOOR CUTOUT LOWER THRESHOLD ATTACH FITTING STATION 607 LOWER AFT FASTENER MOUNT HOLE IS CORRODED. REMOVED AND REPLACED PER SRM 51-40-02-0G.