What was found
INSPECTION TYPE:C2 AFT/BULK CARGO COMPARTMENT NR 2 FLOOR PANEL HAS EXCESSIVE CORROSION UNDERNEATH THE MBA SYSTEM. FLOOR PANEL OUT OF LIMITS, FABRICATED NEW FLOOR PANEL PER SRM 53-00-53-1A, SRM 51-40-05-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 AFT/BULK CARGO COMPARTMENT NR 2 FLOOR PANEL HAS EXCESSIVE CORROSION UNDERNEATH THE MBA SYSTEM. FLOOR PANEL OUT OF LIMITS, FABRICATED NEW FLOOR PANEL PER SRM 53-00-53-1A, SRM 51-40-05-06.