What was found
INSPECTION TYPE:6C FX - SURVEY SEQUENCE 323-F1-02 A PROTRUDING HEAD FASTENER AREA DENT AND 2 LOC. DENT CLOSE TO THE EXISTING FLUSH REPAIR FOUND. SURVEY SEQUENCE 323-F1-02 LOCATION A FASTENER REMOVED AND REPLACED AS PER HX RS R53-31-36297 REV A. EXTERNAL AND INTERNAL DETAIL VISUAL INSPECTION AND HFEC INSPECTION CARRIED OUT AS PER HX RS R53-31-36297 REV A. NIL DEFECT FOUND CRACK FREE. THIS REPAIR CLASSIFIED AS A CATEGORY A REPAIR. REF IPXA EO B767-5330-33045-A.