As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C AFT CARGO STA 1085 RBL 25 BELOW FLOOR SUPPORT BEAM ATT CLIP CRACK. CRACK LENGTH 0.875 INCH. AFT CARGO COMPT STA 1085 RBL 25 BELOW FLOOR SUPPORT BEAM ATT CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.