What was found
INSPECTION TYPE:C MAIN DECK FLOOR SUPPORT STA 1582 LBL 77 SUPPORT ANGLE FOUND CRACK (CRACK LENGTH 1 INCH). MAIN DECK FLOOR SUPPORT STA 1582 LBL 77 SUPPORT ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C MAIN DECK FLOOR SUPPORT STA 1582 LBL 77 SUPPORT ANGLE FOUND CRACK (CRACK LENGTH 1 INCH). MAIN DECK FLOOR SUPPORT STA 1582 LBL 77 SUPPORT ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.