As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C MAIN DECK FLOOR SUPPORT STA 1582 LBL 75 SUPPORT ANGLE FOUND CRACKED (CRACK LENGTH 1.5 INCH). MAIN DECK FLOOR SUPPORT STA 1582 LBL 75 SUPPORT ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.