What was found
INSPECTION TYPE:C SURVEY SEQ 312-F1-07 FX BETWEEN BS 1197+72 TO BS 1197+88 AND STR 19L - 21L EXISTING REPAIR FASTENER HOLES 3EA DRILLED & INSTALLED AT MACHINED RADIUS AREA. FX BETWEEN BS 1197+72 - 1197+88 & STR 19L-21L, ORG MAT'L 202473-0.200IN MACHINED SKIN WITH REPAIR DOUBLER 202473-0.063IN & REPAIR SIZE 9 X 11.875 INCHES EXISTING REPAIR FASTENER HOLES 3EA AT MACHINED RADIUS AREA REWORKED & FASTENERS 3EA INSTALLED IAW HX RS R53-00-36436 REV A & REPEAT INSP REQUIRED REF EO B767-5330-35079-A.