What was found
INSPECTION TYPE:C SURVEY SEQ 312-F1-06 FX BETWEEN BS 442-463 AND STR 23R - 27R EXISTING REPAIR DOUBLER HAS MANY ABRASIVE SANDING LINES, DEEP COUNTERSUNK FOUND AT SEVERAL LOCATIONS. AT THE EDGE OF REPAIR DOUBLER, FX BETWEEN BS 442-463 & STR 23R-27R EXISTING CUTOUT 2.25" X 3.125" & 0.875" X 1.875" RESP OF ORG MACHINED SKIN 2024T3 AT CUTOUT 0.063". REPAIRED IAW HX RS R53-00-36433 REV A THIS CLASSIFIED A MAJOR CATEGORY B REPAIR WITH MATERIAL 2024T3-0071IN AS DOUBLER (REPAIR SIZE 14.5" X 23.375") REPEAT INSP REQUIRED REF EO B767-5330-35075-A FOR DETAIL.