What was found
INSPECTION TYPE:C MEC COMPT STA 246 RBL 10 FLOORBEAM CLIP FOUND CRACK (CRACK LENGTH 1.5 INCH). MEC COMPT STA 246 RBL 10 FLOORBEAM CLIP REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 45.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C MEC COMPT STA 246 RBL 10 FLOORBEAM CLIP FOUND CRACK (CRACK LENGTH 1.5 INCH). MEC COMPT STA 246 RBL 10 FLOORBEAM CLIP REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 45.