What was found
INSPECTION TYPE:C AFT CARGO STA 1087 LBL 24 BELOW FLOOR CLIP FOUND CRACK (CRACK LENGTH 0.75 INCH). AFT CARGO STA 1087 LBL 24 BELOW FLOOR CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 45.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C AFT CARGO STA 1087 LBL 24 BELOW FLOOR CLIP FOUND CRACK (CRACK LENGTH 0.75 INCH). AFT CARGO STA 1087 LBL 24 BELOW FLOOR CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 45.