As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C FWD CARGO LT LONGERON 48 AT STA 1119 - 6-10 FOUND SPLICE AND LONGERON CORRODED AS MARKED. SPLICE AND LONGERON FASTENERS REMOVED, BETWEEN STA 1099 TO 1119 LONGERON 48L TRIMMED OFF REMOVED. HFEC INSPECTION C/O ON TRIM OUT LONGERON, FOUND NO CRACK EVIDENT. REPAIR LONGERON AND SPLICE FABRICATED. FPI C/O ON FABRICATED PARTS (9EA) AND FOUND NO CRACK EVIDENT. REPAIR LONGERON INSTALLED. NEW SPLICE SUPPORT REWORKED WITH FPI C/O, FOUND NO CRACK EVIDENT. NEW SPLICE INSTALLED.