What was found
INSPECTION TYPE:C2 AFT CARGO BAY FLOOR WEB IS CORRODED AT BS 1600-1620 RBL 2.2 STR 29R TO 30R. FABRICATED NEW AFT CARGO BAY FLOOR WEB AT BS 1600-1620 RBL 2.2 STR 29R TO 30R IAW SRM 51-40-02-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 AFT CARGO BAY FLOOR WEB IS CORRODED AT BS 1600-1620 RBL 2.2 STR 29R TO 30R. FABRICATED NEW AFT CARGO BAY FLOOR WEB AT BS 1600-1620 RBL 2.2 STR 29R TO 30R IAW SRM 51-40-02-0G.